Inverter 8 kW; 2MPPT; 10 years warranty
| Max. efficiency |
98.2%
|
| Dimensions (incl. mounting brackets) |
525 mm x 470 mm x 146.5 mm |
| Weight (incl. mounting brackets) |
17 kg (37.5 lb) |
| IP rating |
IP65 |
Input (PV)
| Recommended max. PV power1 |
12000 Wp |
| Max. input voltage2 |
1100 V
|
| Operating voltage range3 |
140 - 980 V
|
| Startup voltage |
200 V
|
| Rated input voltage |
600 V
|
| Max. input current per MPPT |
13.5 A |
| Max. short-circuit current |
19.5 A |
| Number of MPP trackers |
2 |
| Max. input number per MPP tracker |
1 |
Input (DC Battery)
| Compatible battery model |
LUNA2000-5/10/15-S0, LUNA2000-7/14/21-S1 |
| Operating voltage range |
600 - 980 V |
| Max. operating current |
16.7 A
|
| Max. charge power |
10,000 W |
| Max. discharge power |
8800 W
|
Output (On Grid)
| Grid connection |
Three-phase |
| Rated output power |
8000 W |
| Max. apparent power |
8800 VA
|
| Rated output voltage |
220 V AC / 380 V AC, 230 V AC / 400 V AC, 3 W / N + PE |
| Rated AC grid frequency |
50 Hz / 60 Hz |
| Max. output current |
13.5 A
|
| Adjustable power factor |
0.8 leading ... 0.8 lagging
|
| Max. total harmonic distortion |
≤ 3% |
Output (Off Grid)
| Backup Box |
BackupBox-B1 |
| Max. apparent power |
3300 VA |
| Rated output voltage |
220 V / 230 V |
| Max. output current |
15 A |
| Power factor range |
0.8 leading ... 0.8 lagging
|
Protection Feature
| Input-side disconnection device |
Yes |
| Anti-Islanding protection |
Yes |
| DC reverse polarity protection |
Yes |
| Insulation monitoring |
Yes |
| DC surge protection |
Yes,compatible with TYPE II protection class according to EN/IEC 61643-11 |
| AC surge protection |
Yes,compatible with TYPE II protection class according to EN/IEC 61643-11 |
| Residual current monitoring |
Yes |
| AC overcurrent protection |
Yes |
| AC short-circuit protection |
Yes |
| AC overvoltage protection |
Yes |
| Arc fault protection |
Yes |
| Ripple receiver control |
Yes |
|
Battery charging from grid General Specification
|
Yes |
| Operating temperature range |
-25 °C to +60 °C (-13 °F to +140 °F) |
| Relative operating humidity |
0% - 100% RH |
| Max. operating altitude |
4000 m (13,123 ft.) (Derated above 2000 m) |
| Cooling |
Natural convection |
| Display |
LED Indicators; Integrated WLAN + FusionSolar App |
| Communication |
RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE; 4G/3G/2G via Smart Dongle-4G (Optional)
|
| Nighttime power |
< 5.5 W
|
Optimizer Compatibility
DC MBUS compatible optimizer
SUN2000-450W-P2, SUN2000-600W-P
Standards Compliance (More Available Upon Request)
Safety
EN/IEC 62109-1, EN/IEC 62109-2, IEC 62116
Grid connection standards
G98, G99, EN 50438, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR D4, NRS 097-2-1, IEC61727, IEC62116, DEWA
|